This instrument automatically measures gas volume, internal gas pressure, air content and oxygen concentration for quality control in the bottling process of carbonated drinks, etc.
InquiryPRODUCT
Gas Volume Analyzer
GVA-710
Features
- Fully automatic measurement
Both gas volume and air content in a sample container can be measured with a single measurement.
No personal differences in measurement results by automatic measurement.
Less workload compared to manual measurement.
Much safer compared to the manual method by less contact to alkaline solutions.
- Reduced measurement and preparation time
Reducing time by 30 to 70% compared to the conventional model when measuring air content.
- Support for a variety of samples
Enable to measure cans, bottles, and PET bottles from 160 mL to 2.0 L.
Enable to measure sample container with tamper-resistant cap (double-layered lid).
Enable to measure 500mL PET bottle lightweight containers.
- Output results to external printer or PC using dedicated software
Measurement results can be output to not only an external printer but also a connected PC using dedicated software.
- Method function
Up to 20 methods depending on sample property and measurement items can be registered in the instrument.
The measurement method can be edited on a PC using dedicated software.
- Support for barcode reader
Barcode information such as sample ID affixed on the container can be scanned and transferred using a commercial barcode reader
- Visibility inside the absorbent cylinder
The dissolution status of carbon dioxide gas and air content in the absorbent cylinder can be visually checked by operators.
Specifications
Type | Gas Volume and Air Content Analyzer |
---|---|
Model name | GVA-710 |
Measurement items | 1)Carbonated beverages: Gas volume*1, internal gas pressure, Residual gas volume and its oxygen concentration*2, and air content 2)Non-carbonated beverages: Inside gas pressure |
Measurement range | 1)Pressure: 0.010 to 0.500 MPaG 2)Temperature: 0 to 50 ℃ 3)Residual gas volume: 0 to 30 mL 4)Oxygen concentration: 0 to 21 vol% |
Measurement accuracy | 1)Pressure: ±0.001 MPa 2)Temperature: ±0.05 ℃ 3)Residual gas volume: ± 2 %(in case the volume is 5 mL to 30 mL) ± 0.1 mL(in case the volume is 0mL to 5mL) * When measuring standard gas 4)Oxygen concentration: ± 0.2 vol% |
Measurement time | Gas volume/internal gas pressure: Approx. 90 seconds for one sample Residual gas volume: Approx. 5 to 12 minutes for one sample *It depends on sample and conditions |
Sample container | Various steel cans, aluminum cans, PET bottles, and glass bottles Capacity: Approx. 160 mL to 2.0 L Size: height 85 mm to 315 mm, diameter 53 mm to 110 mm |
Stored data | 500 latest measurement results 20 methods |
External output | 1)RS-232C: 1ch for connection to a printer or a computer 2)USB port: 1ch for data transfer and barcode reader |
Ambient condition | 1)Temperature : 5 to 35 ℃ 2)Humidity : 85 %RH or below |
Power supply | AC 100 V to 240 V ± 10 % 50/60 Hz |
Power consumption | 40 W |
Dimensions | 495(W) × 555(D) × 570(H) mm |
Weight | Approx. 38 kg |
Coating | Alkali resistant coating |
Supplied air pressure | 0.6 to 0.7 MPaG |
*1 Gas volume calculation is based on *A and *B
*A:“Chart 13-2 Table of absorption coefficients of carbon dioxide” in revised Soft drinks supervised by Japan Soft Drink Association
*B:ASBC Methods of Analysis -Beer-13: Dissolved Carbon Dioxide
*2 Oxygen concentration measurement is optional.
Applications
- Soft drinks and brewery
Capable of automatically measuring gas volume / internal gas pressure, air content and oxygen concentration for quality control in the bottling process of soft drinks, etc.
Measurement items | Applications |
---|---|
Gas volume / internal gas pressure (volume of carbon dioxide) | Carbonated drink (PET bottles, metal cans and glass bottles) |
Air content (Residual gas volume) with optional oxygen concentration | Carbonated drink (PET bottles, metal cans and glass bottles) |
Inside gas pressure | Carbonated / non-carbonated drink (PET bottles, metal cans and glass bottles) |
This instrument cannot be applied to the following containers.
・ A sample container with a cork stopper
・ A sample in a specially shaped container
- Supported standards
Control items Measuring items |
Gas volume (internal gas pressure) |
Air content | Gas volume + air content (simultaneous measurement) |
Oxygen concentration Option*1 |
Inside gas pressure |
---|---|---|---|---|---|
Soft drinks Carbonated drink |
A | A | A | S | A |
Soft drinks Carbonated fruit juice |
S | S | S | S | S |
Soft drinks Fruit juice |
- | - | - | - | S |
Soft drinks Coffee |
- | - | - | - | A |
Brewery Beer |
A | A | A | S | A |
Brewery Cocktail with tonic water |
A | A | A | S | A |
Brewery Cocktail with fruit juice |
S | S | S | S | S |
Brewery Local beer |
A | A | A | S | A |
A:All can be measured / S:Some samples can be measured / -:Not available
*1 :Oxygen concentration can be measured if the measured gas volume is over 8mL.