PRODUCT

Gas Volume Analyzer
GVA-700

This measuring instrument automatically measures gas volume / internal gas pressure, air content and oxygen concentration for quality control in the bottling process of carbonated drinks, etc.

Inquiry

Features


  • Only by setting a sample container on the sample stage, all the procedures are performed automatically; punching, depressurizing, stirring of a sample, absorption of measurement gas and so on.

  • By continuously rotating a sample container, the balance pressure of gas and sample temperature in the container are measured and calculated into gas volume / internal gas pressure, which are displayed on the LCD.

  • Furthermore, carbon dioxide in the sample gas is absorbed into alkaline solution to leave only nitrogen and oxygen, and then calculate air content using the residual gas volume and oxygen concentration, which are displayed on the LCD.

  • Data printing is available by connecting an external printer to the RS-232C port and 100 measurement results can be recorded in a USB flash drive via the USB port.

The features of GVA-700 are as follows.


  1. No personal error/Fully automated measurement.

  2. Less work/Less possibility to contact alkaline solutions.

  3. Improved maintainability

    With the detachable front cover, easy to maintain the sniffing valve and the filter.

  4. Compact size, space saving

    Size: 495(W) x555(D) x570(H) mm

    (Conventional model : 670(W) x505(D) x680(H) mm)

    Easy to secure the installation space with the slide cover.

  5. Inside the absorption cylinder is visible.

    Inside of the absorption cylinder can be checked visually.

  6. Improved software

    Store 20 methods and 100 measurement results.

  7. USB flash drive

    Load methods and store measurement results with a USB flash drive.

Specification

Measuring items 1)Gas volume / internal gas pressure of carbonated drink
2)Gas volume / internal gas pressure of carbonated drink,air content and oxygen concentration
3)Inside gas pressure of non-carbonated drink
Measuring range Pressure :
55 to 10cmHg and 9.8kPa to 0.490MPa(0.1 to 5.0kgf/cm2G)

Temperature :
0 to 50℃

Residual gas volume :
0 to 30mL(Residual gas volume after the absorption of alkaline aqueous solution)

Oxygen concentration :
0 to 21%(Oxygen concentration measurement is not available when the residual gas volume is 8mL or less.)
Measurement accuracy Pressure :
+/- 0.001MPa(+/- 0.01kgf/cm2G)

Temperature :
+/- 0.05℃

Residual gas volume :
+/- 2% (for 5mL or over and 30mL or less) for the measured value
+/- 0.1mL (for 0mL or over and 5mL or less) for the measured value

Oxygen concentration :
+/- 0.2%
Calibration Gas volume measuring unit :
Pressure sensor-zero : pressure gauge for calibration 0.000MPa(0.00kgf/cm2G)
Pressure sensor-span : pressure gauge for calibration 0.490MPa (5.00Kgf/cm2G)
Temperature sensor : standard thermometer, pure water

Air content measuring unit :
Pressure sensor-zero : pressure gauge for calibration 0.000MPa(0.00kgf/cm2G)
Pressure sensor-span : pressure gauge for calibration 0.098MPa (1.00Kgf/cm2G)

Oxygen measuring unit :
Oxygen sensor : automatic calibration during pretreatment (manual calibration is possible)
Temperature sensor : room temperature
Measurement time For measuring gas volume / internal gas pressure only : approximately 90 seconds for one sample
For measuring gas volume, air content and oxygen concentration : 6 to 16 minutes for one sample
Note: Measuring time varies according to sample and condition
Sample container PET bottles : 2.0L or smaller (190mL cans, various PET containers)
Maximum container : 110 (φ) x 320 (H) mm
Display 16-digit and 1-row LCD (with backlight)
Number of main unit stored data Measurement conditions are storable to the main unit up to 20 sets
Measurement data as many as the latest 100 samples are storable
By using a USB flash drive, can be taken out in a CSV format
Calculation Gas volume :
Calculation of gas volume / internal gas pressure by using the balance pressure inside the sample container and sample temperature.
Calculation formula for the soft drink standard*1 or the EBC standard*2 can be selected.

Air Content :
Calculation of air content by using the residual gas volume and oxygen concentration after absorbing carbon dioxide in the alkaline aqueous solution
External output RS-232C 1ch :
For an external printer or an external computer
1) Compatible printer : IDP-100、DP-600
2) Printout data : Date and time, Measurement mode, Sample No.,
Gas volume (V/V, g/Kg), Internal gas pressure (MPa, Kgf/cm2G), Pressure (MPa, Kgf/cm2G,cmHg), Temperature(℃), Air content (mL), Oxygen concentration (%), Residual gas volume (mL)

USB 1ch :
For method entry, data storage
Ambient condition Temperature : 5 to 35℃
Humidity : 85%RH or below
Power supply Voltage : AC100V to 240V +/- 10V
Frequency : 50/60Hz +/- 1Hz
Power consumption 40W
Coating Alkali-resistance
Dimensions 495(W)×555(D)×570(H) mm
Weight Approximately 38kg
Supplied air pressure Instrument air : pressure of 0.490 to 0.686MPa (5 to 7kgf/cm2G)

*1 :According to “Chart 13-2 Table of absorption coefficients of carbon dioxide” in revised Soft drinks overseen by Japan Soft Drink Association
*2 :According to ASBC Methods of Analysis -Beer-13: Dissolved Carbon Dioxide

Applications

  • Soft drinks and brewery

Can automatically measure gas volume / internal gas pressure, air content and oxygen concentration for quality control in the bottling process of soft drinks, etc.

Measurement items Application
Gas volume / internal gas pressure (volume of carbon dioxide) Carbonated drink
(PET bottles, metal cans and glass bottles)
Air content *measurement capability of oxygen concentration (option) Carbonated drink
(PET bottles, metal cans and glass bottles)
Inside gas pressure Carbonated / non-carbonated drink
(PET bottles, metal cans and glass bottles)

This measurement instrument cannot be applied to the following containers.
・ A sample container using a cork
・ A sample container of a special shape

  • Supported standard
Control items
Measuring items
Gas volume
(internal gas pressure)
Air content Gas volume
+ air content
(simultaneous measurement)
Oxygen
concentration
Option*1
Inside
gas
pressure
Soft drinks
Carbonated drink
A A A S A
Soft drinks
Carbonated fruit juice
S S S S S
Soft drinks
Fruit juice
- - - - S
Soft drinks
Coffee
- - - - A
Brewery
Beer
A A A S A
Brewery
Cocktail with tonic water
A A A S A
Brewery
Cocktail with fruit juice
S S S S S
Brewery
Local beer
A A A S A

A:All can be measured / S:Some samples can be measured / -:Not available
*1 :
Oxygen concentration can be measured if its volume is over 8mL.

Catalog

■General-Catalog.pdf

■Gas Volume Analyzer GVA-700.pdf

Protection of Personal Information and Use of Cookie

This website uses cookies on some pages in order to ensure customers’ comfortable use of the website. When you use this website, please agree to our use of cookies.
If you continue to browse this website even without agreeing to our use of cookies, we consider that you have consented to our use of cookies. You can block cookies by changing your browser settings.