PRODUCT

Karl Fischer Moisture Titrator (Coulometric titration)
MKC-710D

MKC-710D is a Karl Fischer moisture titrator (Coulometric titration)
developed to support DI (Data Integrity) based on GMP (Good Manufacturing Practice).

Inquiry

Features

・Access Restrictions

Operators are authenticated to log on by an operator ID and password.
Only one operator can log on the system and operators can be changed via the logon/logoff function. Up to 100 operators can be registered, and an ID and password are registered for each operator.
Only one operator can log on even when 2 channels are connected.
An operator cannot log off during measurement.

・Rights Administration

You can assign the authorities to edit and set the functions to each operator.
There are five preset rights groups, and you can also create up to 10 rights groups arbitrarily according to the usage at your site.
Reliability improved by assigning each operator to a rights group.

・Electronic Approval / Electronic Signature

The electronic approval workflow consists of five stages: Check, Confirmation, and Approval, are in sequence, as well as denial, and unchecked status.
The signature level cannot be skipped, and always has to be signed in the Check, Confirmation, and Approval sequence.
A password is required when signing.
The signature details can be checked in the signature log.

Data integrity support functions without a PC

  • Dl support function

Access Restrictions : Operator authentication by operator ID and password
Rights Administration : Each operator is assigned to a specific right group
Audit Trail : Operation histories are automatically recorded
Electronic Approval / Electronic Signature : Electronic approval and signature based on the workflow
Backup / Restoration : Automatic backup with the predetermined period
Archive / Archive View : Data storage. Archive data can be viewed on the main control unit
Data Capacity : The remaining capacity can be checked any time via an icon on the main screen
Security Settings : Password length and lockout settings can be set
LIMS Connection : Data output to LIMS systems


  • The MKC-710D contains functions to support compliance with the following:

・European Pharmacopoeia Chapter 2.5.32. WATER: MICRO DETERMINATION: VERIFICATION OF ACCURACY
・Japanese Pharmacopoeia Eighteenth Edition Chapter 2.48: Water determination (Karl Fischer Method):
 2.4 Suitability of determination

  • Large color TFT-LCD with a touch panel (8.4-inch)
  • The main control unit and a titrator are separately located by wireless (Bluetooth(R)).
  • Measurement results can be saved in PDF files.
  • The Water content can be displayed in real time.
  • Energy saving designed.
  • Maximum 2.6mgH2O/min of electrolysis speed.

Specifications

Type Karl Fischer Moisture Titrator
Model MKC-710D
Standard configuration MCU-710D+MKC-710+Manual Solvent Change unit
Measuring method Water content : 1ug to 300mg (depends on reagent)
Bromine index : 8ug to 300mg
Measurement cell 2-Component or 1-Component
Precision Relative standard deviation : less than 0.3% (n=10)
*Per KEM standard measurement conditions and standard liquids
Display resolution 0.1μg
Control method Constant current pulse time control
Endpoint detection Alternate current polarization method with a twin platinum electrode
EP sense method Selective drift stability or limit measurement time
Required solvent 2-Component cell : Anolyte 100mL , Catholyte 5mL
1-Component cell : Anolyte 150mL
Key operation Touch panel
Displays 1) 8.4-inch color LCD 800 x 600 dots
2) English / Japanese / Mandarin Chinese
3) Simultaneous 2-channel display
Calculation Concentration of water content, statistics data processing (mean, SD and RSD) and automatic averaging of blank value and factor value
Data storage Method: 120 (per channel)
Measurement results: 5,000 samples (per channel)
Operation history: 100,000 (Total for 2 channels)
DI support function Access Restrictions: Operator authentication by operator ID and password
Rights Administration: Each operator is assigned to a specific right
Audit Trail: Operation history is automatically recorded
Electronic Approval / Electronic Signature: Electronic approval and signature based on the workflow
Backup / Restoration: Automatic backup with the predetermined period
Archive / Archive View: Data storage. Archived data can be viewed on the main control unit
Data Capacity: The remaining capacity can be checked any time via an icon on the main screen
Security Setup: Password length and lockout settings can be set
LIMS Connection: Data output to LIMS systems
External I/O RS-232C port x4 :
for Dot matrix printer , Electronic balance , Data Capture Software (SOFT-CAP) , Evaporator , Multiple sample changer

USB ×1 :
for USB flash drive , Thermal printer , A4 printer , Keyboard , Barcode reader , Foot switch , USB HUB

LAN ×1 : for Personal computer (PC)
Extensibility Measuring instrument :
Karl Fischer Moisture Titrator (MKV-710/MKC-710)
One of those instruments can be added

Evaporator ADP-611

Multiple sample changer : CHK-501
Ambient condition 1) Temperature : 5 to 35°C
2) Humidity : 85%RH or below (no condensation)
Power source AC100 to 240V +/- 10% 50/60 Hz
Dimensions Touch panel controller : 225(W) x 190(D) x 42(H) mm
Titration unit : 141(W) x 292(D) x 244(H) mm
Stirrer : 107(W) x 206(D) x 340(H) mm (not incl. Solvent Change unit)
Solvent Change Unit : 240(W) x 140(D) x 405(H) mm (not incl. tubing)
Weight Touch panel controller : Approx.1.5kg
Titration unit : Approx.3.0kg
Stirrer : Approx.2.0kg
Solvent Change Unit : Aprox.0.6kg
Conformity standard CE marking EMC : EN61326-1 LVD : EN61010-1

Standards

ASTM D1123 Standard Test Methods for Water in Engine Coolant Concentrate by the Karl Fischer Reagent Method


ASTM D1533 Standard Test Method for Water in Insulating Liquids by Coulometric Karl Fischer Titration


ASTM D3401 Standard Test Methods for Water in Halogenated Organic Solvents and Their Admixtures


ASTM D4672 Standard Test Method for Polyurethane Raw Materials: Determination of Water Content of Polyols


ASTM D4928 Standard Test Method for Water in Crude Oils by Coulometric Karl Fischer Titration


ASTM D5460 Standard Test Method for Rubber Compounding Materials—Water in Rubber Additives


ASTM D6304 Standard Test Method for Determination of Water in Petroleum Products, Lubricating Oils, and Additives by Coulometric Karl Fischer Titration


ASTM D6869 Standard Test Method for Coulometric and Volumetric Determination of Moisture in Plastics Using the Karl Fischer Reaction (the Reaction of Iodine with Water)


ASTM E1064 Standard Test Method for Water in Organic Liquids by Coulometric Karl Fischer Titration


European Pharmacopoeia / 2.5.32. WATER: MICRO DETERMINATION


ISO 10101-3 Natural gas -- Determination of water by the Karl Fischer method -- Part 3: Coulometric procedure


ISO 12937 Petroleum products -- Determination of water -- Coulometric Karl Fischer titration method


ISO 14897 Plastics -- Polyols for use in the production of polyurethane -- Determination of water content


ISO 15512 Plastics -- Determination of water content


ISO 760 Determination of water -- Karl Fischer method (General method)


JIS C2101 Testing methods of electrical insulating oils


JIS K0068 Test methods for water content of chemical products


JIS K0113 General rules for methods of potentiometric, amperometric, coulometric, and Karl Fischer titrations


JIS K1557-2 Plastics -- Polyols for use in the production of polyurethane -- Part 2: Determination of water content


JIS K2275-3 Crude petroleum and petroleum products -- Determination of water -- Part 3: Coulometric Karl Fischer titration method


JIS M8211 Iron ores -- Method for determination of combined water content


JIS M8250 Iron ores -- Determination of hygroscopic moisture in analytical samples -- Gravimetric, Karl Fischer titration and mass-loss methods


United States Pharmacopeia–National Formulary / 38 <921> WATER: DETERMINATION


Software

Option

Catalog

■General-Catalog.pdf

■Karl Fischer Moisture Titrator (DI support model) MKV-710D MKC-710D.pdf

Protection of Personal Information and Use of Cookie

This website uses cookies on some pages in order to ensure customers’ comfortable use of the website. When you use this website, please agree to our use of cookies.
If you continue to browse this website even without agreeing to our use of cookies, we consider that you have consented to our use of cookies. You can block cookies by changing your browser settings.