Resolving problems of viscosity measurements which the conventional measurement methods could not realize.
The world’s first new method “EMS (Electro Magnetically Spinning) method” changes common sense of viscometer.
PRODUCT
EMS Viscometer
EMS-1000S
EMS Viscometer website
This is special website only for introduction of EMS-1000S EMS Viscometer. Please visit the website.
https://www.ems-viscometer.com
Features
EMS viscometer is a new type innovative viscometer that changed the common sense of viscosity measurement in the world for the first time.
By applying torque to the spherical probe in the sample remotely from the outside of the sample container using the force of the magnetic field, we succeeded in completely separating the sample from the device.
We have prepared a state-of-the-art viscosity analytical technology with easy-to-use software and a spherical probe that can be selected according to sample properties, enabling application in a wide field. It is also compatible with small amount, low viscosity measurement which was difficult to measure up to now.
This product adopts part of development results obtained as the framework of JST Japan Science and Technology Agency.
(Patent application No.5093599, US 8,365,582 B2, Applicant name: The University of Tokyo)
・Intuitive and user-friendly GUI(Graphic User Interface) Operation
The measurement result, the status of the sample, the status of the device and the graph plotting the measurement result, show up together on one screen. It is easy to compare the measured data with the data acquired in the past by the powerful search function of the database.
・Prepared spherical probes for matching sample property
Viscosity range: 0.1 to 100,000 mPa・S
To realize more accurate viscosity measurement, you can select a spherical probe according to the properties of the samples.
Water blood polymers resin solvents protein bitumen ink beverage heavy oil.
・Best suited for Very Small Samples and Reuse of Precious Samples
Sample volume required: 300 μL
As small volume of sample as 300 μL / 90 μL (Option) is enough to measure. During measurement the samples are contamination-free.
Samples can be reused for other purposes after measurement.
- Wide Temperature Range
Temperature range : 0 to 200℃
Temperature stability : ±0.1℃
Heating rate : Within 10 minutes(25℃ to 200℃)
- Wide Measuring Range
Viscosity range : 0.1 to 100,000mPa・s(applied φ2.0mm spherical probe)
The standard measuring cell covers the entire viscosity range – no need to use different types of rotors.
- Short Measuring Time
Only 1 second is required to measure samples with a viscosity below 100mPa・s.
Approx. 1 minute is required to measure samples with a viscosity of 10,000mPa・s.
- Rheological Properties
Shear rate : 0.01 to 150s-1 (depending on the sample’s viscosity)
The shear rate can be varied by changing the rotational speed of motor, flow curves can be determined.
- Suitable for Very Small Samples
Sample volume required : 90μL
Measurements of samples which are available in very small quantities can now be performed. During measurement, the samples are not contaminated.
Samples can be used for other purposes after measurement.
Required amount of sample is 300μL in standard specification. By using an optional small volume container, it is possible to measure with a minimum sample volume of 90μL.
- Versatile Measuring Container
No cleaning required.
Measurements are performed in a disposable sample container.
No cleaning required – no cross contamination.
Autoclave sterilization
Ideal for samples which must be measured in a sterile environment such as proteins.
Suitable for measurements under anaerobic conditions
Sealed sample container. This allows to perform measurements in an inert-gas atmosphere.
Applications
Type | EMS Viscometer Electro Magnetically Spinning Viscometer |
---|---|
Model | EMS-1000S |
Method of measurement | Electro Magnetically Spinning Method (EMS) |
Viscosity measuring range | 0.1~1,000mPa・s(Aluminium alloy spheres φ1.5mm:Option) 0.1~100,000 mPa・s (Aluminium spheres φ2mm) 10~1,000,000 mPa・s (Aluminium spheres φ4.7mm) 100~100,000 mPa・s(Titanium spheres φ5mm:Option) |
Measurement accuracy | repeatability : RSD 3%(*1 according to KEM’s standard measuring conditions) accuracy : ±10%(*1 according to KEM’s standard measuring conditions) |
Minimum sample amount | 90μL(Small container and Aluminium spheres φ2mm:Option) 300μL (Aluminium spheres φ2mm) 700μL (Aluminium spheres φ4.7mm) 700μL (Titanium spheres φ5mm, option) |
Temperature | Range : 0~200℃ (*2) / 0~50°C(Small container :Option) Stability : ±0.1℃ |
Motor rotation speed | Range : 500~1,000 rpm Stability : ±3% |
Ambient conditions | Temperature : 10~30℃ Humidity : 85% RH max. (no condensation) |
Storage conditions | Temperature : -20~60℃ Humidity : 85% RH max. (no condensation) |
Power supply | Main unit : AC 200~240V±10% or AC 100~120V±10% 50/60Hz Control PC : 100~240V±10% AC 50/60Hz (power adapter) |
Power consumption | Main unit : Approx.150W (Max 600W) Control PC : Approx. 20W |
Dimensions | Main unit : 356(W)×347(D)×335(H)mm |
Weight | Main unit : Approx. 24kg |
CE marking | EMC : EN61326-1 LVD : EN61010-1 Laser safety : EN60825-1 |
Laser | Wavelength : 660 nm(Red) Beam Divergence : Parallel to the Junction : 10° Perpendicular to the Junction : 17° Maximum output power : 130mW in CW Operation |
*1 :
Repeatability is indicated by the relative standard deviation when the viscosity range is 10 to 1000mPa·s and the measurement is carried out 5 times continuously without changing the equipment conditions (sample, spherical probe and container combination).
*2 :
When setting the preset temperature below room temperature, please prepare dry air for dew condensation prevention. Also, when setting the temperature below 10°C, keep the ambient temperature below 20°C.
Applications
Option
-
Key Code for Low Viscosity Measurement (ROM)
A key code that permits the use of φ1.5 mm aluminum alloy probes that measure low viscosity regions with high accuracy.
-
Kit for Titanium probe
for measuring corrosive samples includes Titanium spheres φ5.0 mm (50 pcs)
-
Kit for Small Container
for small containers includes heat soaking tube, hook holder, small container with lid φ8 mm (100 pcs)and Aluminum spheres φ2.0 mm (50 pcs)
Catalog
■General-Catalog.pdf
■Viscometer_EMS-1000S.pdf
Video
-
Product introduction, EMS Viscometer EMS-1000S
The EMS viscometer is widely used in the field of viscosity analysis such as polymers, pharmaceuticals and fine chemicals.
-
[144sec] High viscosity measurement for shorter time, EMS Viscometer EMS-1000S, Kyoto Electronics.
When measuring with 4.7mm sphere probe, colored or highly viscous samples can be measured in a short period of time.